Oil storage
Production, refining, and distribution of petroleum products require many different types and sizes of storage tanks. Small bolted or welded tanks might be ideal for production fields while larger, welded storage tanks are used in distribution terminals and refineries throughout the world. Product operating conditions, storage capacities, and specific design issues can affect the tank selection process.
Storage tanks
Types of storage tanks
Storage tanks come in all sizes and shapes. Special applications might require tanks to be rectangular, in the form of horizontal cylinders, or even spherical in shape. Horizontal cylinders and spheres are generally used for full pressure storage of hydrocarbon or chemical products. For the purpose of this page, we focus on the atmospheric or low-pressure storage tank widely used from the production fields to the refinery. The most common shape used is the vertical, cylindrical storage tank. Gross capacities can range from 100 bbl to over 1.5 MMbbl in a single storage tank. Corresponding tank sizes range from approximately 10 ft in diameter to over 412 ft in diameter for some of the largest floating-roof tanks ever constructed.
Fig. 1 shows a 312-ft diameter floating-roof storage tank for crude oil storage at a large refinery. The photograph was taken during construction and shows the single deck, pontoon-style external floating roof.
Production tanks construction practices
The type of construction selected for a storage tank depends on the size of tank required and might be dependent on the type of product being stored, the location and space available for storage, prevailing weather or site-specific conditions, and local safety or environmental considerations.
Riveted, bolted, and shop welded tanks
Although the earliest storage tanks used by the petroleum industry were constructed from various types of wood, we will concern ourselves with tanks fabricated from steel or optional nonmetallic materials. Before the development and perfection of welding processes, petroleum storage tanks used either bolted or riveted construction techniques. The tanks would be designed and supplied as segmental elements for final assembly on site.
Riveted tanks dating back to the early 1900s can still be found around the world—many still in service. It is safe to say, however, that recurring maintenance costs and increased environmental and safety concerns dictate that older riveted tanks be replaced with new, state-of-the-art storage tanks.
However, bolted tanks are still used, especially in the smaller sizes typical of produced liquid storage. The fourteenth edition of American Petroleum Institute (API) Spec. 12B, Bolted Tanks for Storage of Production Liquids provides standard designs for capacities from 100 bbl to 10,000 bbl. Current suppliers of bolted tanks can provide capacities up to 40,000 bbl or more depending on the storage application.
Generally, bolted tanks are fabricated either from 12- or 10-gauge steel or several nonmetallic materials. If not galvanized or furnished with a protective coating for corrosion protection, bolted steel construction might not have the expected service life provided by welded-steel tanks. Welded-steel tanks are constructed of thicker plate materials that can be designed to provide some corrosion allowance.
One alternative to bolted construction is the shop welded storage tank. The size and capacities of this type of tank are limited primarily by the method of transportation used to transfer the shop built tank to the final production site. The eleventh edition of API Spec. 12F, Shop Welded Tanks for Storage of Production Liquids provides standard designs for capacities of 90 to 500 bbl. Table 1 presents a partial listing of the standard sizes specified in API Spec. 12F. In this table, "working capacity" refers to the maximum amount of oil that can be stored between the oil outlet and the overflow connection.
Shop-welded storage tanks provide the production industry with tanks of adequate safety and reasonable economy for use in the storage of crude petroleum and other liquids commonly handled by the production segment of the industry. A shop-fabricated tank is tested for leaks in the shop, so it is ready for use once it arrives on site. Tanks are transferred from the truck to the final location on site; completed piping connections and the tank is then ready to be brought on line.
A second alternative for bolted construction is the shop fabricated or field assembled nonmetallic storage tank. Nonmetallic tanks customarily are constructed from plastic materials. These have the advantage of being noncorroding, durable, low-cost, and lightweight. Probably the most common type used is the fiberglass reinforced plastic (FRP) tank. FRP tanks are suitable for outdoor as well as indoor applications. Refer to API Spec. 12P, Fiberglass Reinforced Plastic Tanks for minimum requirements for the design, fabrication, and testing of fiberglass reinforced plastic tanks.
The temperature limits of plastic tanks are approximately 40 to 150°F. Because plastic tanks are considered to degrade more quickly than metal tanks when exposed to fire, some operators prohibit the use of plastic tanks in hydrocarbon service.
Color must be added to the outer liner for protection against ultraviolet radiation. The inner liner must be selected for compatibility with the product stored. Protection from mechanical abuse such as impact loads is necessary. Good planning dictates that plastic storage should not be located next to flammable storage tanks. Special attention should be given to local codes, ordinances, and provisions for insurance relative to storing a flammable product in a flammable container.
Field welded storage tanks
Field-welded storage tanks easily meet industry needs for increased storage capacity whether at a remote production site, at the refinery, or at the marketing terminal. As noted, earlier single-tank capacities have exceeded 1.5 MMbbl of storage with tank diameters of 412 ft and shell heights exceeding 72 ft.
As with the smaller bolted storage tanks, API standards have been developed and improved over the years to ensure the tanks meet the safety and operating needs of the petroleum industry. The tenth edition of API Spec. 12D, Field Welded Tanks for Storage of Production Liquids provides standard sizes with nominal capacities from 500 to 10,000 bbl for the production sector.
When larger tanks are required, the industry can refer to the tenth edition of API Standard 650, Welded Steel Tanks for Oil Storage for material, design, fabrication, erection, and testing requirements. The standard covers open-top or fixed-roof storage tanks that generally operate at atmospheric pressures. Design pressures above atmospheric and design temperatures exceeding 200°F may be permitted when additional requirements are met. Table 2 shows the capacity of welded storage tanks as a function of diameter and height.
Current storage options
The petroleum industry has experienced significant changes in the types of products used to feed the refineries around the world. The increased use of petroleum products has prompted the industry to turn to other sources for supply. Changes in product, physical, and chemical properties impose new challenges to the storage tank industry. Environmental and safety requirements continue to be a significant factor in the selection and design of the storage tanks used by the petroleum industry.
The general types of atmospheric storage tanks (AST) in use may be open top tanks (OTT), fixed-roof tanks (FRT), external floating-roof tanks (EFRT), or internal floating-roof tanks (IFRT). Depending on the product, a closed floating-roof tank (CFRT) may even be selected.
The above ground storage tank has evolved with time. Fig. 2 illustrates this trend, which has emphasized improved safety and improved product loss control. Production facilities generally rely on either open-top tanks or fixed-roof tanks operating at or slightly above atmospheric pressure.
Open top tanks
The OTT was one of the first tanks used to store petroleum products. While it provides liquid containment, direct exposure of the liquid surface to the atmosphere assures high evaporative losses, product odors, and increased potential for fires. The OTT has only limited use, primarily for collection of contaminated run-off or wash water and wastewater processes.
Fixed roof tanks
The FRT provides improved containment of product vapors and reduces the potential for fires. The FRT still exposes the liquid surface to the tank vapor space, producing significant product evaporative losses. This increases the possibility of forming a combustible gas mixture in the vapor space for certain more volatile petroleum products. For this reason fixed roof tanks in refineries are generally used for products with vapor pressures less than 1.5 psia. Fixed-roof tank are generally cylindrical in shape. Fixed roof tanks are kept above ground. Fixed roof tank consists of a cylindrical steel shell. The roof of the tank is conical or domed shape. This tank is constructed for both liquid and gas. In order to allow tank to operate at internal pressure a valve is provided on the top of the tanks. The valve prevents release of vapours. Fixed roof tanks are less expensive. They are widely used in storing petroleum products and other liquid chemicals. The air/vapour is pushed in or pushed out the tank depending on the fluid level in the tank. They are least expensive, economical and less maintenance. But at the same time, it has high potential for evaporation loss and may not be allowed per local regulations.
Floating roof tanks
Although not normally used in production operations, floating roof tanks are often used in pump stations or terminals where the crude oil has been stabilized to a vapor pressure of less than 11.1 psia. Floating roof tanks are cylindrical in shape, and they are kept above ground. Floating roof tank is further divided in to two types: external floating roof tank and internal floating roof tank.
External floating roof tank is cylindrical steel shell with opened top. A roof floats on the surface of liquid. The roof rises and falls depend on the liquid level. The floating roof consists of a deck and fittings. The tank is equipped with fittings that are used for operational functions.
Internal fixed roof comprises of both fixed roof and a floating roof. Fixed roof tanks that are used to employ internal floating roof are the tanks in which fixed roof is supported by vertical columns within the tank. It has permanently affixed roof and a roof that floats inside the tanks which rises when liquid level rises and falls with decrease in liquid level.
Floating roof tanks are constructed by considering environmental reasons to limit product loss and air pollutant. The risk of leakage and tank explosion is less in floating roof tank. The problem with the floating roof tank is that rain water and snow get accumulated on the roof. Hence, this create pressure on the roof and it may sink in the liquid stored. This could lead to hydrocarbon vapor release, mechanical damages, environmental damages, explosions, leaks and loss of life.
Horizontal tank
Horizontal tanks are constructed above ground and below ground services. These tanks are constructed of steel and fibreglass-reinforced polyester. The horizontal tanks are constructed by considering length not more than 5 times the diameter. This helps to maintain structural stability. The tank is equipped with gauge hatches, manholes, pressure vacuum vents. The tanks are cathodic protected to mitigate corrosion.
Pressure tank
Pressure tanks are used to store high pressure fluids. Pressure tanks can be constructed into spherical and cylindrical shape. Spherical structures are stable and strong structure because there is even distribution of stress on the surface of the tank. Spherical tanks are costly. Spherical tanks are also equipped with vacuum vent and manholes. Spherical tanks have smaller surface area per unit volume due to its shape. Hence, rate of heat transfer from the surrounding environment is less which is an advantage of spherical tank. On the other hand, cylindrical pressure vessel are not strong in comparison to spherical tanks. But cylindrical pressure tank are most commonly used because they are less expensive.
LNG Storage tank
LNG storage tank is used only for liquified natural gas storage tank and not for different petroleum and oil products. This type of storage tank can be constructed above ground and below ground depending upon the requirement. The LNG storage tanks have double cylindrical structure where the inner cylinder contains the LNG while the outer cylinder contains the insulation materials which develops the ability to store LNG at very low temperature of -162ºC. The temperature and pressure in the tank will continue to rise if the LNG vapours are not released. LNG is kept at liquid state at very low temperatures. Auto-refrigeration process is followed in which the temperature in the tank remains constant if the pressure is kept constant by allowing the boil of gas to escape from the tank.
Thinks to keep in mind to ensure protection from leaks and corrosion
1. The tanks are protected cathodically. In these anodes connected with current supply system are installed in the tank. Sometimes, galvanic anodes are also used. But nowadays cathodic protection is no longer used to prevent corrosion and leaks.
2. Regular monitoring and inspection of tanks must be done to minimize the chance of disaster.
3. Install leak detection monitoring device on the tank.
4. Try to install tanks in basement rather than in outdoors. If tanks are located outdoors, ensure they are properly supported on a concrete base. Ensure fittings and joints are part of safe storage system and all the areas around these fittings and joints are free and kept clear of snow or ice.
5. Never install a used oil tank.
6. Ensure no flammable objects come into contact of tanks. Guide and give knowledge to the workers and employees about the serious issues that may occur due to misconduct or by a small mistake.
7. Make sure tank bears an Underwriters Laboratories of Canada (ULC) label, ensuring it is certified to a national standard.
Pressure vacuum valves
The evolution of hydrocarbon vapors is dependent on the product’s physical characteristics, the operating pressure of upstream equipment, tank storage conditions, and tank operations. In production operations, the fluid entering a tank often comes from a higher-pressure source (separator, treater, or other production vessel). As the fluid enters the tank, a portion of the fluid will "flash" to vapor. Depending on tank design, vapors may be directed through pressure vent valves directly to a vent or lighted flare. Alternatively, a vapor recovery compressor (or blower) may be installed to direct vapors vented from storage to downstream compressors for sales or injection. Vacuum relief valves are needed to keep a vacuum from occurring because of tank breathing and pumping operations. If a vacuum develops, the tank roof will collapse. Typically, both pressure and vacuum relief are combined in a single pressure-vacuum relief valve such as that shown in Fig. 3.
Tank appurtenances
Tanks may include a variety of appurtenances depending on the storage application, owner requirements, and applicable design codes. In addition to normal product fill and withdrawal connections, access man-ways and various instrument or gauging connections, a tank can include shell-mounted mixers, internal heaters, platforms, ladders, and pressure/vacuum relief vents.
Floating-roof tanks require special attention to details because many can affect safe operation of the floating roof. In external floating-roof tanks, be sure that the rim seals, rolling ladder, and roof drain(s) are designed to minimize any unbalanced loads in the floating roof structure. Each floating roof should include a single antirotation device designed to limit the rotation of the floating roof while it is free to move up or down within the tank shell.
Some features are required for safe operation of the floating roof while others may be optional based on specific storage requirements. Many of these features affect the low operating levels of the floating roof. Optional details are available to address many of these interference issues, enabling a qualified designer to minimize the product heel while maximizing the working capacity of a floating-roof tank. Figs. 4 and 5 identify several features that must be considered when designing the floating-roof tank.
References
Noteworthy papers in OnePetro
Use this section to list papers in OnePetro that a reader who wants to learn more should definitely read
External links
Use this section to provide links to relevant material on websites other than PetroWiki and OnePetro
See also
Vent system design for storage tanks
Controlling liquid leaks from tanks